ST1

Safety weighing cabin

✓ Maximum user protection when working with hazardous substances

✓ Highest safety level through the use of H14 HEPA filters

✓ Precision when weighing with analytical scales

✓ Vibration-free working

✓ Independent installation with recirculation of room air or internal house exhaust air

Security

Highest level of safety: OEL < 20ng/m³, 50x lower than required for G4 hazardous substances and OEB-5 substances.

Unrivaled protection: Protection of the user and other people in the room against highly potent substances during the entire weighing process. It is not absolutely necessary to wear a protective mask.

Visual and audible alarms: let you know immediately when your intervention is required

 

Filter system

Flexible filtration unit: Optional H14 HEPA filter and/or activated carbon filter for solvent vapors.

Vibration-free filtration: Separate filter unit to avoid vibrations.

Patented HEPA H14 particle filter system: with a low-contamination filter change

 

Weighing

Precision in the weighing process: error-free weighing in the milligram range and the use of highly sensitive micro-analysis scales.

Low-turbulence weighing environment: due to laminar air flow

 

Product features

Standard sizes: Width 900mm, 1200mm or 1500mm; height approx. 700mm each

Installation location: The cabin can be placed on a table or we can supply you with a bench or solid stone table.

Easy cleaning and maintenance: thanks to the robust design of the ST1 safety weighing cabins

 

Our service for you

Comprehensive training: we take over the induction and training of your employees

Also there for you after the purchase: many questions only arise during work. We are here to answer all your questions about the cabin

IQ/OQ qualification: the installation qualification (IQ) and functional qualification (OQ “Operational Qualification”) is included at your site by our team of experts

Versatile installation: Independent installation with recirculation of the room air or connection to the internal house exhaust air.

Functionality

Monitoring the air flow

The cabin monitors the air conditions in the laboratory to ensure that no airflow reaches the user, thus ensuring safety. All ST1 safety weighing cabins are tested according to “European Fume Hood” EN14175 and ASHRAE110 standards.

Aerodynamic design

Rounded edges at the top and sides, so-called flow profiles, prevent hazardous substances from escaping and ensure a laminar air flow. This ensures the precision of the scale and can be compared to a “virtual” glovebox. The air flow is set to 0.4 m/s in accordance with standard 15211 (testing and linking).

Security features

Double waste bags mean that hands do not have to be removed during the weighing process and therefore no hazardous substances are carried out.

An acoustic and visual alarm is triggered if the air flow is disrupted. The sensors for this alarm are located under the arm strip, at the height of the profiled opening of the cabin.

The rear wall (air baffle) of the cabin can be dismantled into two parts, allowing decontamination without having to remove and requalify the scale.

Materials

The base plate is made of ceramic, which can absorb spilled liquids. The body is made of high-quality acrylic glass. This generates no static electricity and at the same time offers very good visibility. The material is 8 mm thick and

Built for longevity

Our cabins are built from the highest quality materials for a long service life. With proper maintenance, they can last a lifetime.

Sizes

ST1- 900 – 90(W)*70(H)*78(D) cm

ST1-1200 – 120(W)*70(H)*78(D) cm

ST1-1500 – 150(W)*70(H)*78(D) cm

Key data

  • Separate filter unit with H14 HEPA filter (99.995 % efficiency)
  • Vibration-free design for precise weighing results
  • Materials without static electricity
  • Ergonomic front and armrest
  • Dual alarm system (audible & visual)
  • Height-optimized design for pipettes

Application et service

Installation, training and maintenance from a single source

Delivery, installation, IQ/OQ qualification and maintenance can be carried out directly for you by our experts.

The measurement of the filter retention rate of the H14 HEPA filter (at least 99.995%) is included in the maintenance as well as the low-contamination filter change after the recommended service life of the particle filter of up to 3 years. You are welcome to arrange a maintenance contract with us directly.

Recommendations and use

Our ST1 safety weighing cabinet is recommended by leading scale manufacturers and is used by leading companies in the pharmaceutical and chemical industries. (prove it!)

Ergonomics

The unique functionality with front opening for operating sensitive microanalysis balances ensures excellent ergonomics for long periods of work. The inclined front and armrest provide additional comfort.

With our Bench, the safety weighing cabin is also optionally height-adjustable.

FAQ

A filter with the classification HEPA H14 is used; a solvent filter can be used as an option.

A visual and audible alarm permanently indicates the protection status.

Yes, we recommend changing the filter every 3 years at the latest. According to legislation, you are obliged to have the filter integrity checked once a year. We will be happy to do this for you.

The modular design of the weighing cabinet allows it to be positioned anywhere in the laboratory. Corresponding substructures are also available as an option.

In Germany, the safety of laboratory employees is monitored by various authorities. The main authorities responsible for this are the trade supervisory offices and the occupational health and safety offices of the federal states.

This is theoretically possible, but should always be discussed with your security department.

There are various options for continuing the exhaust air from the cabin, for example recirculation mode or the optional option of transferring it to the house exhaust air.

No, the unique design of a weighing cabin ensures a constant laminar air flow that allows precise weighing.

Wherever hazardous substances have to be handled and/or weighed.

Once your cabin has been installed, our service team will be available to provide you with detailed product training. Most questions will arise during handling, so we will also be able to help you with any questions that arise at a later date – at your premises or flexibly via an online meeting.

No, you can start immediately after installation. There are other optional accessories, such as anti-static bars, endless waste bags, etc., which make it easier to handle your substances.

We provide you with protection for yourself and the users in your laboratory. We also offer you training courses. We also provide you with the necessary certifications for qualifications and test centers. Our flexible, modular containment systems are made from the highest quality materials and have a very long service life with appropriate maintenance and care.

The following sizes are available:
ST1- 900 – 90(W)*70(H)*78(D) cm
ST1-1200 – 120(W)*70(H)*78(D) cm
ST1-1500 – 150(W)*70(H)*78(D) cm

Yes, the cabins can be optionally equipped with amber light.

The front flap of the cabin allows a large opening so that you can easily place equipment in the cabin. Cleaning is also easy to carry out.

Yes, the weighing cabins are designed for seated activities.

Of course, containment solutions mean restrictions, but our concepts offer you the maximum possible working ergonomics with the highest possible level of personal protection.

Options

  • especially for handling and weighing nanoparticles: the ST1 Nanoprotect safety weighing cabinet with special features for the filtration of nanoparticles.
    The ST1 Nanoprotect offers the highest level of safety on the market: a containment record below 0.005 ppm (i.e. 20x lower than required by the containment standard), a minimum exposure level of 15 nanograms/m3 for handling the most hazardous substances (CMR Cat 1 and OEB 5), and guaranteed weighing accuracy and repeatability (up to 10-7 g under certain conditions). And no vibration and weighing with airflow on.
  • Increase safety by using a double-layer HEPA filter (redundant filter system)
  • Complete the system with an activated carbon filter for protection against solvent vapors
  • External printer stand
  • Second waste system
  • Antistatic bar:

Comparaison

Climate chamberSafety BoxBulkpowder seriesInstrument EnclosureLocal Exhaust Ventilation
ProductsClimate ZoneSafety boxBulkpowder cabinInstrument EnclosureLEV - Local Exhaust VentilationST1
Application
Mobile labXXXXXX
User protection
Device enclosure
Specifications
FilterH14 HEPA filterH14 HEPA filterH14 HEPA filterH14 HEPA filterH14 HEPA filterH14 HEPA filter
Climate controloptionalXXXX
Maximum safetyX
Length1500 mm1200 mm1200 mm1200 mmcustomized mm900 mm
Height750 mm650 mm1000 mm863 mmcustomized mm700 mm
Depth1650 mm1450 mm1650 mm797 mmcustomized mm780 mm
Other sizes available
Custom-built possibleXX
OEL< 20ng/m³< 5ng/m³< 1 μg/m3< 20ng/m³< 20ng/m³< 20ng/m³
Standards15211, ASHRAE110, EN14175/ASHRAE110, EN14175EN14175, ASHRAE110, 15211EN14175, ASHRAE110, 15211EN14175, ASHRAE110, 15211
Application
Weighing
Handling large containersXXXX
Handling solventsXXoptionaloptional
with base frameoptionaloptionaloptionaloptionaloptional
height adjustableXoptionaloptionaloptionaloptionaloptional
Handling DNA samplesXXXXXX
integrated glovesXXXXX
Special features
Inert atmosphereXoptionalXXXX
Bactericidal UV-C lampXXXXXX
patented CAV-SASH front sliderXXXXX

Advice and contact

Do you need more information?
Then please contact us by e-mail or telephone!

Or use the contact form and we will get back to you.

Consulting process

Get advice now - Contact us

Find the right elemental analyzer for your requirements. Our team of experts will support you in your selection and answer all your questions.

Use our contact form for a non-binding consultation or call us directly. We look forward to your inquiry!

Termine 2025

10. September 2025: Lab Supply Chemnitz
23. – 25. September 2025: Powtech Technopharm Nürnberg
24. September 2025: Lab Supply Leverkusen
8. Oktober 2025: Lab Supply Hamburg
12. November 2025: Lab Supply Augsburg

Dates 2025

September 10, 2025: Lab Supply Chemnitz
September 23 – 25, 2025: Powtech Technopharm Nuremberg
24. September 2025: Lab Supply Leverkusen
8. October 2025: Lab Supply Hamburg
12. November 2025: Lab Supply Augsburg